You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
bee-weighter/docs
Peter Babič 42085fb348
insert example data
3 years ago
..
1-strain.fzz finalize schematics 4 years ago
1-strain_bb.jpg add docs about schematics 4 years ago
1-strain_schem.jpg add docs about schematics 4 years ago
2-strain.fzz fix 2-strain breadboard color 3 years ago
2-strain_bb.jpg fix 2-strain breadboard color 3 years ago
2-strain_schem.jpg add docs about schematics 4 years ago
4-strain.fzz fix schematic wire colors 3 years ago
4-strain_bb.jpg update strain docs 3 years ago
4-strain_schem.jpg fix schematic wire colors 3 years ago
README.md update strain docs 3 years ago
bottom.jpg update docs 3 years ago
data.ods insert example data 3 years ago

README.md

Strain connections

Single strain

Individual strain consists of two 1k resistors connected as a voltage divider. Connection with two fixed 1k resistors as a voltage divider creates a full bridge. 50kg max.

Single strain half bridge with two additional 1k resistorsbreadboard view

Single strain half bridge with two additional 1k resistorsschematic

Double strain

Using two single strain half bridges together forms a full bridge. 100kg max.

Two single strain half bridges togerher breadboardview

Two single strain half bridges togerher breadboardschematic

Quadruple strain

Using four single strain half bridges together again forms a full bridge, with the resistance doubled. 200kg max.

Two single strain half bridges togerher breadboardview

Two single strain half bridges togerher breadboardschematic